A Guide to Industrial Power over Ethernet

Power over Ethernet sends data and DC power down one Ethernet cable. This guide covers the IEEE 802.3af, 802.3at and 802.3bt standards, PoE classes 0–8, power budgets, active vs passive PoE, PSE vs PD and industrial PoE.

TypeWhite paper
Published2 Oct 2022
AuthorAndrew WhitehouseManaging Director
Reading time26 min

Power over Ethernet (PoE) is a family of IEEE 802.3 standards that send DC power and data down the same twisted-pair Ethernet cable, from a power sourcing equipment (PSE) port on a switch, injector or computer to a powered device (PD) such as a camera, wireless access point, panel PC or edge computer. One cable of up to 100 metres replaces a data run and a separate mains or DC supply, and the PSE only switches power on after it has detected a compliant device at the far end.

Three standards set the power levels. 802.3af (PoE) supplies up to 15.4 W per port, 802.3at (PoE+) up to 30 W, and 802.3bt (PoE++) up to 60 W or 90 W by using all four pairs. The device always receives less than the port supplies, because some power is lost as heat in the cable, so a deployment is sized on the figure at the device and on the switch or computer’s total PoE budget, not on the per-port maximum alone.

This guide is the reference view for industrial projects: the IEEE standards and classes side by side, how detection and classification work, how to size a PoE budget, active versus passive PoE, the PSE and PD roles, what changes in a cabinet, a vehicle or on a pole, and how far PoE can reach. For short answers on single topics, see our FAQs on what PoE is, PoE vs PoE+ vs PoE++ and how much power PoE delivers.

Key points · 5 points

Key takeaways

01One cable, power and data
PoE carries DC power, nominally around 48 V, alongside Ethernet data on the same twisted pairs, up to 100 m from the PSE to the device.
02Four power levels, nine classes
802.3af, 802.3at and the two 802.3bt types give 15.4, 30, 60 and 90 W at the port; classes 0–8 tell the PSE how much to reserve.
03The device gets less than the port
Cable loss means a device sees about 12.95, 25.5, 51 or 71.3 W, so size every device on its PD figure.
04Budget beats per-port figures
A switch or computer often cannot run every port at full power at once; the total PoE budget decides how many devices it can carry.
05Industrial PoE starts with the supply
Most PSEs need a 48–57 V feed, so low-voltage vehicle and cabinet supplies need a switch or computer with a built-in PoE boost.
02Standards

IEEE PoE standards compared

Every PoE standard is an amendment to IEEE 802.3, and each newer one stays compatible with devices built to the older ones. The table is the quick reference: power is quoted at the PSE port and at the PD after the worst-case 100 m of cable.

Standard Common name Type Classes Power at the PSE Power at the PD Pairs used PSE voltage Published
IEEE 802.3af PoE Type 1 0–3 15.4 W 12.95 W 2 44–57 V DC 2003
IEEE 802.3at PoE+ Type 2 0–4 30 W 25.5 W 2 50–57 V DC 2009
IEEE 802.3bt PoE++ (4PPoE) Type 3 0–6 60 W 51 W 2 or 4 50–57 V DC 2018
IEEE 802.3bt PoE++ (4PPoE) Type 4 0–8 90 W 71.3 W 4 52–57 V DC 2018

The 2018 standard is the one most often misquoted. Type 3 covers classes 5 and 6, at 45 W and 60 W from the PSE, and it can also power older class 0–4 devices over two pairs. Type 4 covers classes 7 and 8, at 75 W and 90 W, and always uses all four pairs. Some datasheets round the Type 4 figure to 100 W, which is a marketing number rather than an IEEE one; the standard caps the PSE at 90 W and the device at 71.3 W.

Before 802.3bt, several switch makers sold pre-standard 60 W schemes, and those devices do not always interoperate with standard Type 3 equipment. If an older device is labelled with a proprietary scheme rather than an IEEE type and class, check it against the PSE before you order. The PoE vs PoE+ vs PoE++ FAQ linked above covers the names in more detail.

Why the device gets less than the port

The PSE figure includes the power lost in the cable, which turns into heat along the run. 802.3af assumes a worst-case loop resistance of 20 Ω, the figure for older Category 3 cable, which costs up to about 2.45 W at 350 mA. 802.3at and 802.3bt assume Category 5e or better at about 12.5 Ω, which is why a 30 W port leaves 25.5 W at the device and a 90 W port leaves 71.3 W. Shorter runs lose less, but the standards size every link for the full 100 m, and so should a power budget.

Standards

How does Power over Ethernet work?

PoE is safe to plug into any Ethernet device because the PSE does not apply full voltage until it has checked what is on the other end. The sequence takes a fraction of a second and runs every time a cable is connected or a device restarts.

Stage What happens Typical voltage on the pairs
Detection The PSE applies a low voltage and looks for the PD’s signature resistance of about 25 kΩ. A device without the signature, such as a laptop, gets no power About 2.7–10.1 V
Classification The PSE raises the voltage and measures the current the PD draws, which tells it the class and how much power to reserve. 802.3at and 802.3bt use several classification events About 14.5–20.5 V
Power-up The PSE switches on the full output and limits the inrush current while the PD’s input capacitors charge 44–57 V, depending on type
Operation The PD runs and keeps drawing a small maintain power signature so the PSE knows it is still connected 44–57 V
Disconnect If the device is unplugged or the signature stops, the PSE removes power within about 300–400 ms 0 V

That handshake is what the IEEE calls active PoE, and it is why a PoE switch can share a rack with ordinary devices. It is also the step that passive PoE leaves out, which is covered in the section on active vs passive PoE below.

Data and power share the same wires because the power is DC and the data is not. Ethernet magnetics in every port couple the data signal across a transformer, and the PSE applies the DC voltage between the centre taps of two pairs, so it appears as a common-mode voltage the data receivers never see. On a Gigabit link, which uses all four pairs for data, the power simply rides on top.

Mode A, Mode B and four-pair power

Two-pair PoE can use either set of pairs. Mode A puts power on the pairs on pins 1–2 and 3–6, the same pairs that carry data on a 10/100 link. Mode B uses pins 4–5 and 7–8, the spare pairs on 10/100. A standards-compliant PD must accept either, with either polarity, so the choice belongs to the PSE. Our FAQ on PoE Mode A vs Mode B has the full pin map.

RJ45 pins Pair 10/100 data role Mode A (two-pair) Mode B (two-pair) Four-pair 802.3bt
1 and 2 Pair 2 (orange in T568B) Transmit Power, one polarity None Power
3 and 6 Pair 3 (green in T568B) Receive Power, other polarity None Power
4 and 5 Pair 1 (blue) Unused None Power, one polarity Power
7 and 8 Pair 4 (brown) Unused None Power, other polarity Power

802.3bt adds four-pair power and, with it, two kinds of device. A single-signature PD presents one signature across both pair sets and is powered as one load. A dual-signature PD presents a separate signature on each pair set, so each half can be classified and powered on its own. Most cameras and access points are single-signature; dual-signature designs tend to appear in devices with two independent power rails. The cable must be at least twisted pair to Category 5e for 802.3at and 802.3bt.

03Classes

PoE classes 0–8 explained

A PoE class is the power level a device asks for during classification. The PSE reserves that amount from its budget, so the class decides how many devices a switch or computer can power, not just whether one device will run.

Class Standard and type Power reserved at the PSE Power available at the PD Typical devices
0 802.3af and later, Type 1 15.4 W 0.44–12.95 W Devices that do not declare a class; the PSE reserves the full Type 1 level
1 802.3af, Type 1 4 W 3.84 W Sensors, small IoT nodes, door controllers
2 802.3af, Type 1 7 W 6.49 W VoIP phones, fixed IP cameras without heaters
3 802.3af, Type 1 15.4 W 12.95 W Fixed dome and bullet cameras, single-radio access points
4 802.3at, Type 2 30 W 25.5 W PTZ cameras, multi-radio access points, small PoE-powered panel PCs
5 802.3bt, Type 3 45 W 40 W Access points with several radios, PoE lighting
6 802.3bt, Type 3 60 W 51 W Video conferencing, thin clients, camera clusters with IR
7 802.3bt, Type 4 75 W 62 W Heated outdoor PTZ cameras, PoE displays
8 802.3bt, Type 4 90 W 71.3 W PoE displays and panel PCs, building controllers, heated PTZ housings

Class is a ceiling, not a measurement. A class 4 camera may draw 12 W on a mild day and 25 W when its heater and IR illuminator are on, and a PSE that allocates by class will reserve 30 W for it either way. Many managed PSEs can instead negotiate the real figure with the device over LLDP, which 802.3at introduced as data link layer classification, and 802.3bt adds Autoclass, where the device draws its maximum briefly at start-up so the PSE can measure it. Both free up budget, and both are worth checking for on a datasheet when the switch is near its limit.

When a PSE runs out of budget, it refuses or removes power from the lowest-priority port. Managed industrial PoE switches let you set that priority per port, so a door controller stays on while a monitor goes dark, and unmanaged models usually fix it by port number.

04Budget

How much power does PoE deliver to a whole system?

Per-port figures say what one device can have. The PoE budget says what all of them can have at once, and it is the number that most often limits an industrial build. The table works through a typical roadside cabinet.

Device Quantity Class Reserved per port at the PSE Reserved in total
Fixed IP camera with IR 4 3 15.4 W 61.6 W
PTZ camera with heater 1 6 60 W 60 W
Wireless access point 1 4 30 W 30 W
Allocated by class 6 devices – – 151.6 W
Add 15–20% headroom – – – About 175–180 W

On that load, an eight-port switch with a 240 W budget, such as the Antaira LMP-1204G-SFP-bt with four 90 W PoE++ ports and four PoE+ ports, has room for the cameras, the access point and a later addition. A computer with four PoE+ ports and a 50 W budget would not, even though each of its ports can deliver 25.5 W on its own.

Computers show the gap between per-port and total power most clearly. The Neousys NRU-52S series has four 802.3bt ports that can each deliver up to 90 W to one camera, but its PoE budget is 50 W across the ports when passively cooled, or 144 W with the optional fan kit. The Sintrones IBOX-602P-IP66 supplies 15.4 W on each of its two M12 ports within a 32 W budget. Neither is a limitation once it is planned for; both are reasons to add up the devices before choosing the computer. Our white paper on PoE power budgeting for multi-camera edge AI works through larger examples.

Input voltage changes the budget

A PSE has to produce 44–57 V at the port, so most PoE switches and cards expect a 48–55 V DC supply, and the PoE budget is limited by what that supply can deliver. Switches with a built-in boost converter accept a lower input and step it up, but the budget usually falls with the voltage. The Antaira LNP-0500G-bt-24, for example, gives a 180 W PoE budget from a 24–55 V DC supply and 90 W from 12 V DC. Size the power supply for the PoE budget plus the switch or computer’s own draw, and add the losses of the supply itself.

PoE sizing · 5 steps PoE

Sizing a PoE budget in five steps

The same five checks apply whether the PSE is a switch, a PoE card or a computer.

  1. Devices

    List and classify

    List every powered device with its IEEE class and its worst-case draw, including heaters, IR illuminators and motors that switch on in cold or dark conditions.

  2. Allocate

    Class or LLDP

    Add up the power reserved at the PSE. Use the class figures unless the PSE and every device support LLDP power negotiation.

  3. Headroom

    15–20% spare

    Add 15–20% for future devices, firmware changes and the cold start, when many devices draw their maximum at once.

  4. Cable

    Run length and bundles

    Check that every run is within 100 m on Category 5e or better, and allow for heat where many powered cables share a tray or conduit.

  5. Supply

    Input and budget

    Choose a PSE whose total budget covers the load at the input voltage available, then size the DC supply for the budget plus the PSE’s own draw.

05Compared

Active vs passive PoE

Active PoE is the IEEE kind described above. Passive PoE applies a fixed voltage, commonly 24 V or 48 V and sometimes 12 V, to the cable whenever the injector is switched on, with no detection, no classification and no disconnect. It persists because it is cheap and simple, and some outdoor radios and small devices are built for it. Our FAQ on active vs passive PoE goes further.

Feature Active PoE (IEEE 802.3af/at/bt) Passive PoE
Detection before power Yes, a 25 kΩ signature check No
Classification Yes, classes 0–8 No
Voltage 44–57 V DC, set by the standard Fixed, often 24 V or 48 V, set by the maker
Safe with non-PoE devices Yes, they receive no power No, any connected device receives the voltage
Interoperability Any compliant PSE with any compliant PD Only matched injector and device
Disconnect on unplug Yes, within a few hundred milliseconds No
Typical use Industrial, enterprise and surveillance networks Some wireless radios and low-cost devices

Feeding passive 48 V into a port that is not built for it can damage the port, and an IEEE device on a 24 V passive injector will usually not start at all. In an industrial network, where devices from several makers share switches and the people who maintain it change over the years, specifying IEEE-compliant PoE end to end removes a whole class of site faults. Where a passive device has to stay, give it its own matched injector and label the cable.

Compared

PSE vs PD: switches, injectors and computers

Every PoE link has one PSE and one PD, and the same piece of equipment can be either. A switch is usually a PSE, a camera is usually a PD, and computers can be both. Our FAQ on PoE PD vs PSE explains the terms, and the table shows where each role turns up in an industrial system.

Equipment Usual role How it supplies or draws power Example from our range
PoE switch (endspan) PSE Power on the switch ports themselves, two or four pairs Antaira LNP-0800G, eight 30 W PoE+ ports on a 240 W budget
PoE injector (midspan) PSE Adds power to a cable between a non-PoE switch and the device Used where a switch has no PoE or one device needs more power
Computer with PoE ports PSE Powers cameras and sensors directly, with no separate switch Vecow ECX-3200MX PEG, four 2.5GbE PoE+ ports on M12
PoE card in a computer PSE A PCIe card adds PoE ports, fed from the computer’s power supply Vecow PE-6004HF, four 90 W PoE++ ports, up to 200 W in total
Computer powered by PoE PD Runs from one cable, with no local power supply EverFocus eNVP-JOX-IV-F4004, a 60 W PoE-PD input
Panel PC powered by PoE PD A touch screen and computer on one cable Winmate R15IE3S-PCC3-POE, an 802.3at PD port at 25 W

Do I need a PoE switch or a PoE injector?

A PoE switch is the better choice when several devices need power, because one budget, one supply and, on managed models, one place to monitor and restart ports cover them all. A PoE injector suits one or two devices on an existing non-PoE switch, or a single device that needs more power than the switch can give. Injectors are also called midspans, and on 10/100 links they usually use the spare pairs, Mode B.

Choosing between managed and unmanaged PoE switches follows the same logic as any other switch, with two extras: managed models let you see each port’s draw and power-cycle a hung camera remotely. Our guide to managed vs unmanaged switches sets out the wider choice.

Computers on both sides of the link

As a PSE, a PoE computer powers and connects a set of cameras or sensors directly, so a vision or surveillance node needs no separate switch. That is the common pattern in industrial NVR systems and in NVIDIA Jetson PoE systems running AI on the camera feeds, and our guide to PoE in surveillance and NVR systems covers it in depth. Board-level designs can start from PoE single board computers, and existing computers can gain ports through Ethernet and PoE frame grabbers.

As a PD, the computer itself runs from one cable, which removes the need for a local power supply in a ceiling, on a pole or in a sealed enclosure. The power available sets the class of computer: 25.5 W at 802.3at suits a low-power processor and a small screen, while 802.3bt opens the way to more capable systems. Our FAQ on whether a computer can be powered by PoE sets out the limits, and PoE panel PCs and PoE monitors put a screen on the same single cable. We configure, image and test every PoE computer and panel PC with its power settings and devices in mind before it ships.

06Industrial

Industrial PoE: what changes outside the office

The IEEE standards are the same in a factory as in an office. What changes is everything around them: the temperature, the supply, the electrical noise, the vibration and how hard it is to reach a failed device.

Factor Office or enterprise PoE Industrial PoE
Operating temperature About 0–40 °C in a ventilated room Often −40 to 75 °C on extended temperature models; check the rating at full PoE load
Power input Mains AC into a rack switch 24 V or 48 V DC in a cabinet, 12 V or 24 V on a vehicle, redundant inputs
Low-voltage supplies Rarely needed Built-in boost from 12–24 V DC on selected switches and computers
Connectors RJ45 RJ45 in cabinets; M12 X-coded or D-coded where there is vibration or water
Mounting 19-inch rack DIN rail, wall, pole or vehicle; rack in control rooms
Surge and EMC Office levels Higher surge and ESD protection, IEC 61000-4 immunity testing, isolated ports on some models
Approvals General IT safety UL 61010-1, Class I Division 2, EN 50155 or EN 50121 for rail, depending on the model
Remote recovery Site visit Per-port power cycling, PoE ping alarms and relay alarm outputs

Temperature and budget interact. Many PoE switches and computers reach their full budget only within part of their rated range, or with a fan fitted, so read the derating notes as well as the headline figure. The same applies to cables: a bundle of 90 W runs in a closed tray heats up, and ISO/IEC and TIA guidance on bundled PoE cabling recommends larger conductors or smaller bundles where many high-power links share a route. Our FAQ on the industrial temperature range explains the common ratings.

Vibration is the other industrial difference. An RJ45 plug held by a plastic clip can work loose on a vehicle or a machine, so rail and vehicle PoE uses M12 connectors, X-coded for Gigabit and above and D-coded for 100 Mbit/s. Our guide to M12 connectors covers the codings, and M12 Ethernet switches bring the same sealed connectors to the network side. On rolling stock, look for computers designed to EN 50155.

Applied examples on our site include PoE computers running ANPR barrier control and embedded systems with PoE in a smart parking scheme.

Industrial

How far can PoE run?

PoE follows Ethernet’s own limit: 100 m per link, made up of up to 90 m of fixed cable and 10 m of patch leads. Beyond that, the data link may still work, but the voltage at the device falls and neither the data nor the power is guaranteed.

Need Approach What to check
Up to 100 m Standard PoE on Category 5e, 6 or 6A cable Solid copper conductors; avoid copper-clad aluminium
100–300 m PoE extenders, each regenerating data and passing power on Power lost at each hop; budget falls with every extender
Hundreds of metres to kilometres Fibre to a PoE switch or PoE media converter near the devices A local DC supply at the far end
Single-pair links on machines and vehicles Power over Data Lines (IEEE 802.3bu) on single-pair Ethernet Device and connector support for single-pair Ethernet

Cable category matters for power as well as speed. Category 5e is the minimum for 802.3at and 802.3bt, and the larger conductors often used in Category 6 and 6A cable, typically 23 AWG, run cooler at high power. Our FAQs on Cat5e vs Cat6 and Cat6 vs Cat6A compare them, and single-mode vs multimode fibre covers the fibre side of a long run. For single-pair links on machines and vehicles, see our white paper on single-pair Ethernet.

Check · 7 checksPoE

Specifying PoE for an industrial build

Seven checks that catch most PoE problems before the hardware is ordered.

  1. 01

    IEEE type and class

    Confirm every device’s 802.3 type and class, and avoid proprietary or passive schemes unless they are isolated.

  2. 02

    Total budget

    Add up the class figures, add headroom, and compare the result with the PSE’s total PoE budget, not its per-port figure.

  3. 03

    Budget conditions

    Check whether the full budget needs a fan, a minimum input voltage or a lower ambient temperature.

  4. 04

    Input supply

    Match the PSE’s input range to the site supply, and size the supply for the PoE budget plus the PSE’s own draw.

  5. 05

    Cable and connectors

    Use Category 5e or better within 100 m, and M12 where vibration or water would loosen or flood an RJ45.

  6. 06

    Port control

    Decide whether you need per-port priority, scheduling or remote power cycling, which usually means a managed PSE.

  7. 07

    Approvals

    Check the temperature, EMC, rail or hazardous-area approvals the site needs against each product’s datasheet.

07FAQs

Power over Ethernet: common questions

Quick answers

What is Power over Ethernet and how does it work?

One cable carries data and DC power. The PSE detects a compliant device, reads its class, then applies about 48 V across two or four pairs. The data and the DC power share the wires without interfering.

What is the difference between PoE, PoE+ and PoE++?

Power per port. PoE (802.3af) supplies up to 15.4 W, PoE+ (802.3at) up to 30 W and PoE++ (802.3bt) up to 60 W on Type 3 or 90 W on Type 4.

How many watts can PoE deliver?

Up to 90 W at the port and 71.3 W at the device. That is the 802.3bt Type 4 limit over 100 m of cable. Most cameras need far less, typically 4–25 W.

What are PoE classes?

Power levels a device declares. Classes 0–8 tell the PSE how much power to reserve, from 4 W for class 1 to 90 W for class 8.

What is the difference between a PSE and a PD?

The PSE supplies, the PD draws. Switches, injectors and some computers are PSEs; cameras, access points and PoE-powered computers are PDs.

Is passive PoE safe to use with IEEE devices?

Not without care. Passive PoE applies voltage without a handshake, so it can damage devices that do not expect it, and IEEE devices often will not start on it.

How far can PoE run?

100 m per link. Use PoE extenders for a few hundred metres, or fibre to a PoE switch or media converter for longer runs.

Do I need a PoE switch or a PoE injector?

A switch for several devices, an injector for one. An injector adds power to a single link on an existing switch; a PoE switch powers many devices from one budget.

Does PoE reduce network speed?

No. Power and data use the same pairs without affecting each other, so a PoE port runs at the same Ethernet speed as one without power.

FAQs

Power over Ethernet FAQs

  1. What Is PoE?

    PoE, or Power over Ethernet, sends electrical power and network data down the same Ethernet cable. A powered port on a switch, injector or computer supplies DC power, at around 48 V, to a device such as an IP camera, access point or sensor, so that device needs no separate power supply or mains socket where it is mounted.

  2. PoE vs PoE+ vs PoE++: The 802.3af, 802.3at and 802.3bt Standards

    PoE, PoE+ and PoE++ are the three generations of IEEE Power over Ethernet. PoE (802.3af) supplies about 15 W per port, PoE+ (802.3at) about 30 W, and PoE++ (802.3bt) 60 W (Type 3) or 90 W (Type 4). PoE and PoE+ use two of the four cable pairs; PoE++ can use all four.

  3. How Much Power Does PoE Deliver?

    PoE delivers up to about 15 W per port (802.3af), PoE+ up to about 30 W (802.3at), and PoE++ up to 60 W or 90 W (802.3bt), all at around 48 V DC (44 to 57 V). Some power is lost in the cable, so the device receives a little less than the source supplies.

  4. Active vs Passive PoE: What Is the Difference?

    Active PoE follows the IEEE 802.3af, at and bt standards: the source checks for a PoE device and agrees a power class before applying around 48 V DC. Passive PoE is non-standard: it puts a fixed voltage, often 24 V or 48 V DC, on the cable with no handshake, so it can damage equipment not built for it.

  5. PoE PD vs PSE: What Is the Difference?

    In a PoE link the PSE (power sourcing equipment) supplies the power and the PD (powered device) draws it. A PoE switch, injector or PoE computer acting as a source is the PSE; a camera, phone, access point or PoE-powered display is the PD. The IEEE 802.3 standards define how the two detect, classify and power each other.

  6. PoE Mode A vs Mode B: What Is the Difference?

    PoE Mode A carries power on the data pairs, pins 1, 2, 3 and 6. Mode B uses the other two pairs, pins 4, 5, 7 and 8. The power source chooses the mode, and every IEEE-compliant powered device must accept either. 802.3bt (PoE++) can use all four pairs at once for higher power.

  7. Can a Computer Be Powered by PoE?

    Yes. A PoE powered computer takes its power as a powered device (PD) from the same Ethernet cable that carries its data, so it needs no mains socket or local power supply. Low-power computers, gateways and thin clients run from PoE+ (802.3at); larger systems need PoE++ (802.3bt) at up to about 71 W at the device.

  8. What Is a PoE Switch?

    A PoE switch is a network switch whose ports supply DC power as well as data over Ethernet cable. It connects devices such as IP cameras, access points and sensors and powers them at the same time, so each device runs from one cable without its own power supply or injector. It shares a fixed power budget across its ports.

  9. What Is a PoE Injector?

    A PoE injector is a small device that adds power to an Ethernet cable from a non-PoE switch or router. It sits between the network port and the powered device, taking data in on one port and sending data plus power out on the other, so a single camera or access point can run without a PoE switch.