What Does Intrinsically Safe Mean?

Intrinsically safe means a device or circuit is designed so that the electrical and thermal energy it can release, even when parts fail, is too low to ignite a flammable gas or dust atmosphere. It is a protection method defined in IEC 60079-11, marked Ex ia, ib or ic, and used mainly for low-power instruments, radios and handheld devices.

01

What intrinsically safe means

Intrinsically safe describes electrical equipment designed so that it cannot ignite a flammable atmosphere, because the energy available in its circuits, as a spark or as heat, is kept below the level needed for ignition. The safety is built into the circuit itself rather than provided by a strong box around it, which is where the word intrinsic comes from.

The design must stay safe not only in normal use but also when components fail, wires break or terminals short. How many faults it must survive sets its level of protection. Intrinsic safety is one of several protection concepts recognised under ATEX, IECEx and the North American codes, and the international standard for it is IEC 60079-11; in the US the equivalent is UL 913.

Because the energy limits are tight, intrinsic safety suits low-power equipment: pressure and temperature transmitters, gas detectors, radios, phones, scanners and some tablets. A full-size panel PC usually needs too much power, so it uses a different method.

02

How an intrinsically safe system fits together

Intrinsic safety is assessed as a system, not just a device. A typical loop has four parts.

  • //
    Intrinsically safe apparatus. The device in the hazardous area, such as a sensor or handheld, marked Ex ia, ib or ic. Battery-powered devices carry their own certified battery pack.
  • //
    Associated apparatus. A zener barrier or galvanic isolator in the safe area that caps the voltage and current sent into the field. Its marking puts the level in square brackets, such as [Ex ia], because the device itself sits outside the zone.
  • //
    Interconnecting cable. Kept separate from other circuits and often identified with a light blue sheath or marking. Its capacitance and inductance count towards the loop’s stored energy.
  • //
    The system check. The barrier’s maximum output must sit within what the field device can accept, including cable effects. This entity check is recorded in a descriptive system document.
FAQ · 01
Is intrinsically safe the same as non-incendive?
No. Intrinsically safe equipment stays safe with one or two faults, so it can go into the most hazardous areas. Non-incendive equipment is only safe in normal operation, which limits it to Division 2 and Zone 2.
Read the full FAQ —
03

Intrinsic safety compared with other protection methods

Intrinsic safety prevents ignition by limiting energy. The other main methods contain, exclude or avoid ignition instead. The table sets them side by side.

Method Ex code How it prevents ignition Highest zone Typical equipment
Intrinsic safety Ex ia, ib, ic Limits energy so sparks and hot surfaces cannot ignite the gas, even with faults Zone 0 (ia) Sensors, transmitters, radios, handhelds
Flameproof (explosion proof) Ex d Strong enclosure contains an internal explosion and cools escaping gas Zone 1 Motors, switchgear, lighting, enclosed computers
Increased safety Ex eb, ec Construction avoids arcs, sparks and hot spots in normal use Zone 1 (eb) Terminal boxes, motors, luminaires
Pressurisation Ex p Clean air or inert gas keeps the flammable atmosphere out Zone 1 Analyser houses, purged cabinets and computers
Encapsulation Ex m Potting compound seals ignition sources away from the atmosphere Zone 0 (ma) Solenoids, sensors, small electronics

The most searched comparison is intrinsically safe vs explosion proof. Explosion-proof, or flameproof, equipment assumes the gas will get inside and that ignition may happen, and relies on a heavy enclosure to stop the flame escaping. Intrinsically safe equipment assumes the gas is everywhere and makes ignition impossible. Explosion-proof designs handle high power but are heavy and must stay sealed; intrinsically safe designs are light and can be opened or worked on live, but only at low power.

04

How to tell if a device is intrinsically safe

Look at the marking, not the brochure. An intrinsically safe device carries a hazardous area marking that includes ia, ib or ic, such as Ex ia IIC T4 Ga, together with an ATEX, IECEx or UKCA certificate number, or in North America an intrinsically safe listing to UL 913 for a stated class, division and group. The level decides where it can go: ia suits Zone 0, ib Zone 1 and ic Zone 2 only, as our ATEX zones explainer sets out. A product described as “intrinsically safe” with no marking or certificate is not.

Level ic is worth noting because many rugged mobile devices use it. Our rugged tablets include a 10.1 inch ATEX and IECEx Zone 2 model marked Ex ic IIC T4 Gc, and our rugged handheld computers include a Zone 2 version with Ex ic protection. Both are certified for Zone 2, not Zone 1. Fixed screens are a different case: our hazardous area panel PCs cover Zone 2 and Class I, Division 2 using methods suited to their higher power.

05

Where intrinsically safe equipment is used

Intrinsic safety is common wherever instruments and people work inside zoned areas: refineries, offshore platforms, gas terminals and pipelines in oil and gas, and also chemical and pharmaceutical plants, distilleries, grain and flour handling, mining and wastewater treatment. Typical users are instrument technicians, inspectors and operators carrying radios, gas detectors, thermal cameras, phones, scanners and tablets.

The limits are worth planning for. Power is low, typically a few watts at most per circuit, so screens are dimmer and processors slower than on standard devices. Batteries, chargers and accessories are part of the certification, and certificates often say batteries may only be changed or charged in a safe area.

06

Quick answers on intrinsically safe

Intrinsically safe: common questions

Is intrinsically safe the same as ATEX?

No. ATEX is the EU legal framework. Intrinsic safety is one of the protection methods an ATEX-certified product can use.

What does Ex ia mean?

The highest level of intrinsic safety. Ex ia equipment stays safe with two independent faults and can be used in Zone 0, the most hazardous gas zone.

How does an intrinsically safe barrier work?

It caps the energy sent into the hazardous area. A zener barrier diverts excess voltage to earth and limits current with resistors; a galvanic isolator does the same job without an earth connection.

Can intrinsically safe equipment be used in Zone 0?

Only at level ia. Ex ib suits Zone 1 and Ex ic suits Zone 2. Check the level in the marking before taking a device into a zone.

What colour is intrinsically safe cable?

Often light blue. IEC 60079-14 allows light blue to identify intrinsically safe circuits, so other cables should avoid that colour.