How a rack server is built
A rack server is a server in a flat metal chassis made to bolt into a standard 19-inch equipment rack. Rails let it slide out for service, and a full-height rack, often 42U, holds dozens of servers alongside switches, storage and power distribution.
The rack dimensions come from the EIA-310 standard. The front panel is 19 inches (482.6 mm) wide, the opening between the rails is about 450 mm, and height is counted in multiples of the rack unit. One rack unit, written 1U, is 1.75 inches or 44.45 mm. A 2U server is twice that height, a 4U server four times.
Inside, a rack server looks like any other server: processors, ECC memory, drives and network cards. What sets it apart is the packaging. Drives load from the front in hot-swap caddies, power supplies slide out from the back, and fans pull air front to back so a whole row of racks can share a cold aisle and a hot aisle.
What 1U, 2U and 4U mean
Height decides how much fits inside. A taller chassis takes more drives, taller expansion cards and larger heatsinks, and it cools high-power parts more quietly.
| Height | Front panel height | Typical expansion | Typical use |
|---|---|---|---|
| 1U | 44.45 mm | 1 to 3 low-profile or riser PCIe cards | Web, network and edge appliances |
| 2U | 88.9 mm | Full-height cards, often 2 to 4 GPUs | Virtualisation, storage, AI inference |
| 3U | 133.35 mm | Full-height cards, more drive bays | Storage and GPU systems |
| 4U | 177.8 mm | Up to around 8 double-width GPUs | AI training, rendering, large storage |
Card and drive counts vary widely by model, so treat the expansion column as typical rather than a rule. The rack also needs depth: standard server racks are commonly 1,000 mm or more deep, while short-depth chassis fit shallower telecom and wall-mount cabinets. Leave room in the plan for cable management, a top-of-rack switch, power distribution and a rack-mount UPS, which all take their own share of the rack height.
Rack, tower and blade servers
Rack servers are one of three main server form factors. Each suits a different kind of site.
-
//
Rack server. Standard chassis that stack in a shared rack. Suits server rooms and data centres with several servers, switches and a UPS in one place.
-
//
Tower server. An upright case like a large desktop. Suits a single server in an office or a shop floor with no rack, and is quiet and easy to reach.
-
//
Blade server. Thin server boards that slide into a shared enclosure with common power, cooling and networking. Suits large sites that need many servers in the least space.
High-density servers
A high-density server puts more compute into each rack unit. Two common designs are multi-node servers, which fit two or four independent servers into one 2U chassis with shared power supplies, and GPU-dense servers, which fit four to eight accelerators into 2U to 4U.
Density moves the problem to power and cooling. A rack of GPU servers can draw tens of kilowatts, far more than many older server rooms were designed for, so the rack’s power feeds, cooling and airflow have to be planned with the servers. Remote management through a baseboard management controller (BMC) becomes essential when there are too many machines to visit one by one.
Rack servers outside the data centre
Rack servers also run in control rooms, vehicles, ships and telecom cabinets, where the rack is the better form factor for the installation. These sites change the specification: shallower chassis, DC power input, wider operating temperatures and resistance to shock and vibration.
Our rack mount servers cover that range, from 1U edge AI servers with redundant AC or DC power to a 2U fanless rack server rated for wide temperatures and a 2U defence server tested to MIL-STD-810G and MIL-STD-461. For GPU-heavy inference near the machines, our edge AI servers fit several high-power GPUs in a rugged chassis. Our guide to AMD EPYC Embedded for edge servers covers processor choice. A rack mount KVM console gives local screen and keyboard access in the same rack.
Quick answers on rack servers
Rack servers: common questions
How tall is 1U?
1.75 inches, or 44.45 mm. That is one rack unit under EIA-310. Equipment is usually slightly shorter than its nominal height so neighbouring kit can slide in and out.
How wide is a server rack?
19 inches at the mounting flanges. The front panel of 19-inch equipment is 482.6 mm wide and the opening between the rails is about 450 mm. The rack cabinet itself is usually 600 or 800 mm wide.
What is a server rack?
The frame or cabinet that holds rack equipment. A server rack has four vertical rails with a repeating hole pattern every 1U. Servers, switches, storage, power distribution and UPS equipment bolt to the rails.
Is a rack server better than a tower server?
It depends on the site. A rack server suits several servers in one place with shared power and cabling. A tower server suits a single server where there is no rack and quiet operation matters.
What is a blade server?
A server on a single board that slides into a shared enclosure. The enclosure, or chassis, supplies power, cooling and networking to every blade, so each blade carries only processors, memory and a little storage. Blades suit large sites that need many servers in a small space.
What is a 2U server?
A rack server 2U, or 88.9 mm, tall. A 2U chassis takes full-height expansion cards and more drives than 1U, which makes it a common size for virtualisation and GPU inference.
We build rack servers with the processors, memory, GPUs, storage and operating system fitted as standard, and validate each one before it ships. Tell us your rack depth, power feeds and workload, and we will specify the server to match.