What ISO 5 means
An ISO 5 cleanroom is a room or zone whose air contains no more than 3,520 particles of 0.5 µm or larger per cubic meter, measured to ISO 14644-1. It sits two classes cleaner than the ISO 7 rooms common in electronics assembly, which means a hundred times fewer particles, and it is the cleanest class most pharmaceutical and medical work uses.
ISO 14644-1 sets limits at several particle sizes, and a room can be classified at one or more of them. The table shows the ISO 5 limits beside ISO 7 for comparison.
| Particle size | ISO 5 maximum per m³ | ISO 7 maximum per m³ |
|---|---|---|
| 0.1 µm and larger | 100,000 | Not specified |
| 0.2 µm and larger | 23,700 | Not specified |
| 0.3 µm and larger | 10,200 | Not specified |
| 0.5 µm and larger | 3,520 | 352,000 |
| 1 µm and larger | 832 | 83,200 |
| 5 µm and larger | Not specified; a macroparticle descriptor can be used | 2,930 |
Older documents give ISO 5 a limit of 29 particles at 5 µm. The 2015 edition of ISO 14644-1 removed it, because counts that low cannot be sampled reliably. Under the withdrawn US Federal Standard 209E, ISO 5 was Class 100: no more than 100 particles of 0.5 µm per cubic foot.
How ISO 5 conditions are achieved
People and processes shed particles all the time, so an ISO 5 zone relies on sweeping them away faster than they build up. Most achieve it with unidirectional airflow, often called laminar flow: HEPA-filtered air flows down or across the work zone in parallel streams at an even speed, carrying particles away from the product instead of mixing them around the room. Guidance has long pointed to an air speed of around 0.45 m/s at the working height, although the right figure depends on the process and is proven by testing rather than fixed by the standard.
Whole rooms at ISO 5 are expensive, because the filtered air supply has to cover most of the ceiling. Many sites instead create an ISO 5 zone only where the product is exposed, inside a cleaner background room.
-
//
Laminar flow cabinets and hoods. Benches and hoods that blow filtered air over a small work area. Common in laboratories and hospital pharmacies.
-
//
Isolators and RABS. Sealed enclosures or restricted access barrier systems that separate the operator from the product, used for aseptic filling lines.
-
//
Minienvironments. Enclosed process tools and wafer handling systems in semiconductor fabs, which often run cleaner than ISO 5 inside a less strict room.
-
//
Full ISO 5 rooms. Whole rooms with filtered ceilings, used where large equipment or many operators must work in the clean zone.
ISO 5, GMP Grade A and USP 797
ISO 5 is a particle class only. Regulated industries add their own rules on top of it.
In Europe and the USA, sterile medicines are made under EU GMP Annex 1. Its Grade A, the zone for open product and aseptic connections, must meet ISO 5 both at rest and in operation, and Grade B, the background to Grade A, must meet ISO 5 at rest. Annex 1 also sets microbial limits and expects continuous particle monitoring in Grade A, neither of which ISO 14644-1 covers. In the United States, USP 797 requires sterile preparations to be compounded inside an ISO 5 primary engineering control, such as a laminar airflow workbench or a compounding isolator, normally placed in an ISO 7 buffer room. Our explainer on the ISO 7 cleanroom covers that background class.
Testing and classifying an ISO 5 zone
Classification follows ISO 14644-1. The number of sampling locations comes from a table in the standard based on the floor area, and at each location a particle counter must sample enough air to expect at least 20 particles at the class limit. At 0.5 µm for ISO 5 that works out at around 5.7 liters per location, with a minimum of 2 liters and one minute. A room passes when every location is within the limit.
The test can be run in three states, so a certificate should say which one applies: as built (empty), at rest (equipment installed and running, no people) and in operation (normal working). ISO 14644-2 then sets out a monitoring plan to show the room stays in class, and most sites repeat the classification at least once a year. Pharmaceutical Grade A zones also need airflow visualization, usually smoke studies, to prove the flow sweeps the critical area.
Equipment in an ISO 5 zone
Anything placed inside an ISO 5 zone can shed particles or disturb the airflow, so equipment is kept to a minimum. Computers and screens are usually mounted flush in a wall or behind a window, with the electronics outside the clean zone, and operators use them through gloves. Where a screen does sit in or beside the zone, it should be fanless, fully sealed and smooth, so it adds no particles and survives repeated wiping with sporicidal and alcohol-based agents.
Our guide to clean room computers sets out what to specify for each cleanroom class. For screens near ISO 5 work, our stainless steel panel PCs and fully sealed IP65 panel PCs provide the flat fronts and fanless cooling that cleaning procedures expect.
Quick answers on ISO 5 cleanrooms
ISO 5 cleanrooms: common questions
What class is an ISO 5 cleanroom?
Class 100. Under the old US Federal Standard 209E, ISO 5 was Class 100: no more than 100 particles of 0.5 µm or larger per cubic foot.
Is ISO 5 the same as GMP Grade A?
Not quite. Grade A must meet ISO 5 for particles, but GMP also sets microbial limits, monitoring and airflow requirements that ISO 14644-1 does not.
What is the difference between ISO 5 and ISO 7?
A hundred times the particles. ISO 7 allows 352,000 particles of 0.5 µm per m³, against 3,520 for ISO 5, and usually relies on mixed rather than unidirectional airflow.
What is an ISO class 5 laminar flow hood?
A local ISO 5 zone. It blows HEPA-filtered air over the work surface so the area under the hood meets ISO 5, even when the surrounding room is ISO 7 or ISO 8.
How many air changes does an ISO 5 cleanroom need?
Hundreds an hour, typically. ISO 14644 sets no air change rate. Unidirectional airflow across a whole room usually means several hundred air changes an hour, which is why ISO 5 is often confined to hoods and isolators.
We supply fanless, sealed panel PCs and displays for cleanroom work as part of a complete system, with the mounting and finish matched to the room class and cleaning regime as standard.