How ATEX zones are defined
ATEX zones classify a hazardous area by how often, and for how long, an explosive atmosphere is likely to be present. The definitions come from the ATEX workplace directive 1999/92/EC, and the method for drawing them is set out in IEC 60079-10-1 for gas and IEC 60079-10-2 for dust.
There are six zones in two sets. Zones 0, 1 and 2 cover flammable gases, vapours and mists. Zones 20, 21 and 22 cover combustible dust. In both sets, the lower the number, the more often the hazard is present and the stricter the equipment rules.
The zone decides what equipment is allowed. Most computers and HMIs in hazardous areas are installed in Zone 2, near process equipment where a leak is possible but not expected. Zone 1 and Zone 0 call for more protective designs, such as intrinsically safe or flameproof equipment.
The six ATEX zones compared
The table sets out each zone with a common rule of thumb for how long the atmosphere is present each year. The hours are industry guidance, not part of the directive, but they help when comparing areas.
| Zone | Substance | Explosive atmosphere present | Rule of thumb | Equipment category | Typical example |
|---|---|---|---|---|---|
| Zone 0 | Gas, vapor, mist | Continuously or for long periods | Over 1,000 hours a year | 1G | Inside a tank above the liquid |
| Zone 1 | Gas, vapor, mist | Likely in normal operation | 10 to 1,000 hours a year | 2G or 1G | Around filling points and vents |
| Zone 2 | Gas, vapor, mist | Unlikely, and only briefly | Under 10 hours a year | 3G, 2G or 1G | Around flanges, valves and pumps |
| Zone 20 | Combustible dust | Continuously or for long periods | Over 1,000 hours a year | 1D | Inside silos, hoppers and mills |
| Zone 21 | Combustible dust | Likely in normal operation | 10 to 1,000 hours a year | 2D or 1D | Around bag filling and tipping points |
| Zone 22 | Combustible dust | Unlikely, and only briefly | Under 10 hours a year | 3D, 2D or 1D | Near dust handling plant with good housekeeping |
Equipment rated for a stricter zone can always be used in a less strict one, which is why a category 1 instrument is acceptable in Zone 2. The reverse is never allowed.
Gas zones: 0, 1 and 2
Gas zones are drawn around each source of release, such as a vent, seal or sample point. Their size depends on how much can escape, how fast, how heavy the gas is and how well the area is ventilated.
-
//
Zone 0. Only category 1 equipment, typically intrinsically safe sensors and instruments. Computers are almost never placed here.
-
//
Zone 1. Category 2 equipment, such as flameproof or purged enclosures. Some intrinsically safe handhelds and tablets are certified for it.
-
//
Zone 2. Category 3 equipment, where most hazardous area panel PCs are used, often built to protection concepts such as Ex ec or Ex ic.
-
//
Outside the zones. Standard industrial equipment, often in a control room, connected to the field by certified cabling.
Dust zones: 20, 21 and 22
Dust zones work in the same way but add one hazard gas does not have: layers. Dust that settles on a hot surface can smoulder and ignite, and a layer disturbed by a knock can form a cloud. For that reason, dust-rated equipment states a maximum surface temperature with dust layers in mind, and good housekeeping can shrink or remove a Zone 22.
Dust zones are common in food, grain, wood, pharmaceutical and plastics processing. The equipment is marked D rather than G, and dust groups IIIA, IIIB and IIIC separate combustible fibers, non-conductive dust and conductive dust.
How hazardous area classification is done
Hazardous area classification is the assessment that turns a site’s process information into zones. It works source by source: for each place where a flammable gas, vapor or dust could escape, the assessor decides how often it will be released, how far the cloud can travel before it is diluted below its lower explosive limit, and how well the area is ventilated. In Great Britain the work sits inside the DSEAR risk assessment. The method comes from IEC 60079-10-1 for gas and IEC 60079-10-2 for dust, and many USA refineries, terminals and chemical plants also use the Energy Institute’s Model Code of Safe Practice Part 15, known as EI 15.
The result is a set of drawings showing the type and extent of every zone, usually annotated with the gas group and temperature class of the substances involved. Those three facts are what an equipment supplier needs. The main inputs are:
-
//
Grade of release. A continuous release usually leads to Zone 0 or 20, a primary release, expected now and then in normal operation, to Zone 1 or 21, and a secondary release, only under abnormal conditions, to Zone 2 or 22.
-
//
Ventilation. How strong and how dependable the ventilation is can shrink a zone or change its type. Good, reliable ventilation may turn what would be Zone 1 into Zone 2; poor ventilation can do the opposite.
-
//
Extent. Release rate, pressure, gas density and the lower explosive limit decide how far a zone reaches. Heavier-than-air vapours spread low and collect in pits, trenches and drains.
-
//
Substance data. Flash point, ignition temperature and gas group for gases and vapours; minimum ignition temperature of a cloud and of a layer, and dust group, for dusts.
-
//
Review. The classification is reviewed whenever the process, the substances or the layout change, and kept with the site’s explosion protection records.
Gas groups and temperature classes
The zone says how often a hazard is present. The gas group and temperature class say how easily it ignites, and the equipment marking has to cover both. Equipment rated for a more demanding group can be used for a less demanding one, so IIC equipment also suits IIB and IIA.
-
//
Group IIA. The least easily ignited group, represented by propane. It includes most fuels and solvents, such as petrol vapor, acetone and natural gas in surface industries.
-
//
Group IIB. Represented by ethylene. It includes gases such as hydrogen sulphide and diethyl ether.
-
//
Group IIC. The most easily ignited group, represented by hydrogen and acetylene. Equipment marked IIC suits every gas group.
-
//
Temperature classes. The maximum surface temperature: T1 450 °C, T2 300 °C, T3 200 °C, T4 135 °C, T5 100 °C and T6 85 °C. The class must sit below the ignition temperature of every substance in the area, so a T4 marking suits any gas that ignites above 135 °C.
Who classifies the zones
Zoning is the employer’s job. Under 1999/92/EC, and under the DSEAR regulations in Great Britain, the site must carry out a hazardous area classification, record it on drawings and in an explosion protection document, and review it when the process changes. Specialist consultants often do the assessment, but the duty stays with the site.
The result is a zone drawing that the equipment supplier works from. When asking for a computer or display, give the zone, the gas or dust group and the temperature class from that drawing. Our ATEX explainer shows how those requirements appear in an equipment marking.
ATEX zones and the North American system
North America mainly uses classes and divisions under the US National Electrical Code and the Canadian Electrical Code. Division 1 covers what the zone system splits into Zone 0 and Zone 1, and Division 2 corresponds broadly to Zone 2. The two systems are certified separately, so a Zone 2 product is not automatically approved for Division 2. The US also permits a zone system of its own, in NEC Articles 505 for gas and 506 for dust, which uses Class I Zones 0, 1 and 2 and lines up closely with the IEC approach. Our Class 1 Division 2 explainer compares them in more detail.
Quick answers on ATEX zones
ATEX zones: common questions
What is ATEX Zone 2?
An area where an explosive gas atmosphere is unlikely and brief. It is the least hazardous gas zone and needs category 3 equipment or better. Most hazardous area computers and HMIs are installed here.
What is ATEX Zone 1?
An area where an explosive gas atmosphere is likely in normal operation. It needs category 2 or category 1 equipment, typically flameproof, purged or intrinsically safe designs.
What are DSEAR zones?
The same zones under British law. The DSEAR regulations implement the ATEX workplace directive in Great Britain and use the same Zone 0, 1, 2 and 20, 21, 22 definitions.
Can Zone 1 equipment be used in Zone 2?
Yes. Equipment certified for a stricter zone can be used in a less strict one, provided the gas group and temperature class also suit the site.
Is Zone 0 or Zone 2 more dangerous?
Zone 0. The lower the number, the more often the explosive atmosphere is present, so Zone 0 has the strictest rules.
What is hazardous area classification?
The process of dividing a site into zones. It identifies where flammable gas, vapor or dust could be released, how often and how far it could spread, and records the result as Zones 0, 1, 2 or 20, 21, 22 on drawings.
Our hazardous area panel PCs cover Zone 2 and Class I Division 2 sites. We integrate and validate each system as standard, keeping to the certified configuration, so tell us the zone, gas group and temperature class and we will match the equipment.