The Short Answer
The system comes from the US National Electrical Code and the Canadian Electrical Code. Class II covers combustible dust and Class III fibers. Groups A to D set which gases a product is rated for, from acetylene (A) and hydrogen (B) to ethylene (C) and propane (D).
-
//
Division 1 Covers what the zone system splits into Zone 0 and Zone 1.
-
//
Division 2 Broadly matches Zone 2: hazards only under abnormal conditions.
-
//
Groups A, B, C, D Equipment rated for all four suits the widest range of gases.
-
//
Separate certification C1D2 and ATEX are separate approvals; one does not imply the other.
Why It Matters
Most C1D2 panel PCs are non-incendive rather than intrinsically safe; our intrinsically safe vs non-incendive FAQ explains the difference. The wastewater HMI case study shows a C1D2 HMI in use, and our hazardous area panel PCs cover the range.