01
The Short Answer
L coding lets M12 carry real power. Where an A-coded connector suits a sensor supply, an L-coded connector feeds whole I/O modules and devices, and its distinct key stops it being mistaken for a signal or Ethernet connection.
-
//
Rating Up to 16 A at 63 V DC.
-
//
Contacts 4 or 5, including functional earth on 5-pin versions.
-
//
Standard IEC 61076-2-111.
-
//
Typical use Power for PROFINET devices and field I/O.
02
L Coding and the Other Power Codings
L and T coding cover DC power; S and K coding cover AC. The M12 power codings FAQ compares all four. Our guide to M12 connectors compares every coding, and the M12 coding FAQ explains how coding works.